Technical data 50 Hz 

 

 

Engine type   TCG 2016 V08   V12 C   V16 C
Bore / stroke   mm 132 / 160   132 / 16   132 / 16
Displacement   dm3 17.5   26.3   35.0
Speed   min-1 1,5   1,5   1,5
Mean piston speed   m/s 8.0   8.0   8.0
Length 1)   mm 3,09   3,69   4,09
Width 1)   mm 1,49   1,49   1,59
Height 1)   mm 2,19   2,19   2,19
Dry weight genset   kg 5,34   7   8,45

 

Natural gas applications

NOX ≤ 500 mg / Nm3 6)

 

Engine type   TCG 2016 V08   V12 C V12 C_515 V16 C
Electrical power 3)   kW 400   600 515 800
Mean effective pressure   bar 19.0   18.9 16.2 18.9
Thermal output 4) ±8 % kW 428   654 513 854
Electrical efficiency 3)   % 42.3   42.0 43.2 42.5
Thermal efficiency 3)   % 45.2   45.8 43.1 45.3
Total efficiency 3)   % 87.5   87.8 86.3 87.8

 

Biogas applications

NOX ≤ 500 mg / Nm3 6)

Minimum heating value Hu = 5.0 kWh / Nm3

Sewage gas (65 % CH4 / 35 % CO2)

Biogas (60 % CH4 / 32 % CO2, rest N2)

Landfill gas (50 % CH4 / 27 % CO2, rest N2) 

 

Engine type   TCG 2016 V08   V12 C   V16 C
Electrical power 3)   kW 400   600   800
Mean effective pressure   bar 19.0   18.9   18.9
Thermal output 4) ±8 % kW 393   593   788
Electrical efficiency 3)   % 42.8   42.7   42.8
Thermal efficiency 3)   % 42.0   42.2   42.2
Total efficiency 3)   % 84.8   84.9   85.0

 

Technical data 60 Hz 

 

Engine type   CG 2016 V08 C   V12 C   V16
Bore / stroke   mm 132 / 160   132 / 160   132 / 16
Displacement   dm3 17.5   26.3   35.0
Speed   min-1 1,8   1,8   1,8
Mean piston speed   m/s 9.6   9.6   9.6
Length 1)   mm 3,17   3,77   4,13
Width 1)   mm 1,49   1,49   1,49
Height 1)   mm 2,19   2,19   2,19
Dry weight genset   kg 4,8   6,25   7,03

 

Natural gas applications

NOX ≤ 500 mg / Nm3 6)

 

Engine type   TCG 2016 V08 C   V12 C   V16 C
Electrical power 3)   kW 400   600   800
Mean effective pressure   bar 15.8   15.7   15.7
Thermal output 4) ±8 % kW 445   675   887
Electrical efficiency 3)   % 41.4   41.3   41.6
Thermal efficiency 3)   % 46.0   46.5   46.1
Total efficiency 3)   % 87.4   87.8   87.7

 

Biogas applications

NOX ≤ 500 mg / Nm3 6)

Minimum heating value Hu = 5.0 kWh / Nm3

Sewage gas (65 % CH4 / 35 % CO2)

Biogas (60 % CH4 / 32 % CO2, rest N2)

Landfill gas (50 % CH4 / 27 % CO2, rest N2) 

 

Engine type   TCG 2016 V08 C   V12 C   V16 C
Electrical power 3)   W 400   600   800
Mean effective pressure   bar 15.8   15.7   15.7
Thermal output 4) ±8 % kW 415   632   827
Electrical efficiency 3)   % 41.6   41.4   41.7
Thermal efficiency 3)   % 43.1   43.6   43.2
Total efficiency 3)   % 84.7   85.0   84.9